Parameters in this block control times in a job (such as ending time).

    <time>
    cour_no         = 0.4       # The Courant, Friedrichs, & Lewy (CFL) Number
    nlim            = 100000    # cycle limit
    tlim            = 6.2832e4  # time limit (10 orbits)

tlim: Time to stop integration, in units defined by problem.

nlim: Maximum number of cycles of the main loop before stopping. Set to -1 to stop only on time limit tlim.

cour_no: CFL number, must be less than 1.0 for 1D and 2D CTU integrator, and 0.5 for 2D VL integrator, or 3D.